Business Areas

Major Accomplishments

134

Development of eddy current loss measurement technology considering Harmonics conditions

Customer : Hyundai Motors Namya

Content / Equipment

The purpose of this study is to develop a harmonic rotational magnetic field analysis S/W based on FEM and test device to evaluate and improve the eddy current loss of PM of IPMSM for driving xEV.

2020.05

133

Small Automotive Motor Performance Tester

Customer : Jeonbuk Institute of Automotive Convergence Technology

Content / Equipment

0.1Nm load system (Motor_Max 25,000rpm), 1Nm load system (Motor_Max 25,000rpm), 10Nm load system (Motor_Max 12,000rpm), 50Nm load system (Motor_Max 3,000rpm), cogging torque measuring device, test bed, WT5000 power analyzer, data collection device, 2 sets of constant temperature and humidity chamber, operating SW

  • business-per-122-01.jpg
  • business-per-122-02.jpg
  • business-per-122-03.jpg
  • business-per-122-04.jpg
  • business-per-122-05.jpg
  • business-per-122-06.jpg
  • business-per-122-07.jpg
2020.04

132

CCTV BOX REMOTE CONTROL SECURITY SYSTEM v1.0

Customer : Public Procurement S

Content / Equipment

CCTV BOX REMOTE CONTROL SECURITY SYSTEM v1.0

2020.03

131

Portable Dynamo

Customer : DR. DRIVE

Content / Equipment

  • business-per-125-01.jpg
  • business-per-125-02.jpg
  • business-per-125-03.jpg
2020.03

130

CCTV 함체 보안시스템

Customer : Changnyeong-gun, Gye

Content / Equipment

CCTV Box Remote Control Security System v1.0

  • 176.CCTV_함체_보안시스템_창녕_2.jpg
  • 176.CCTV_함체_보안시스템_창녕_1.jpg
2020-08-11

129

Counter Electromotive Force Tester

Customer : SPG

Content / Equipment

Load system (motor_200W, servo motor), movable box, sample attaching jig

  • business-per-124-01.jpg
  • business-per-124-02.jpg
  • business-per-124-03.jpg
2019.12

128

EV Driving Motor Performance Tester

Customer : Gyeongnam Technopark

Content / Equipment

Load system (Motor_260kW, 500Nm, max 17,000rpm, Siemens SINAMICS Driver), test bed (3500x1800x120, board), WT1800E power analyzer, data collection device, DC power supply unit (400kW, bidirectional), constant temperature and humidity chamber, operating SW, etc.

  • 4 1.jpg
  • 4 2.jpg
  • 중형2.jpg
2019.12

127

Reducer and Actuator Performance Tester

Customer : Gyeongnam Technopark

Content / Equipment

Load system (input 10kW, output 13.5kW, Siemens SINAMICS Driver), gear box (1,000Nm, 1,600Nm, 3,200Nm), bearing unit (50Nm, 1,000Nm, 2,000Nm), test bed (5200x800x800), WT1800E power analyzer, data collection device, DC power supply unit (50kW, bidirectional), operating SW (reducer test mode, actuator test mode), etc.

  • business-per-125-01.jpg
  • business-per-125-02.jpg
  • business-per-125-03.jpg
  • business-per-125-04.jpg
2019.12
Enlarged Image